Proline Promag E 100 Electromagnetic flowmeter

Proline Promag E 100 Electromagnetic flowmeter

You are currently viewing Proline Promag E 100 Electromagnetic flowmeter

The economical flowmeter with an ultra-compact transmitter

Promag E is a streamlined sensor for basic chemical applications. It is the most economical solution for our chemical customers. Combined with the smallest transmitter housing available today it delivers full performance on a smallest footprint. Designed for applications where space is a premium, Promag E 100 will be the preferred choice for system integrators, skid builders and equipment manufacturers.

Benefits

  • Cost-effective sensor – ideal solution for basic requirements
  • Energy-saving flow measurement – no pressure loss due to cross-section constriction
  • Space-saving transmitter – full functionality on the smallest footprint
  • Time-saving local operation without additional software and hardware – integrated web server
  • Integrated verification – Heartbeat Technology™
  • Fully suitable for basic applications in the chemical and process industry.

Device properties

  • Nominal diameter: max. DN 600 (24″)
  • Ex approvals for Zone 2
  • Liner made of PTFE
  • Robust, ultra-compact transmitter housing
  • Local display available
Measuring PrincipleElectromagnetic
Product headlineThe economical flowmeter with an ultra‐compact transmitter. Fully suitable for basic applications in the chemical and process industry.
Sensor featuresCost‐effective sensor – ideal solution for basic requirements. Energy‐saving flow measurement – no pressure loss due to cross‐section constriction. Maintenance‐free – no moving parts. Nominal diameter: max. DN 600 (24″). Ex approvals for Zone 2.
Transmitter featuresSpace‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology. Robust, ultra‐compact transmitter housing.
Nominal diameter rangeDN 15 to 600 (½ to 24″)
Wetted materialsLiner: PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum
Measured variablesVolume flow, conductivity, mass flow
Max. measured errorVolume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
Measuring range4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)
Max. process pressurePN 40, Class 150, 20K
Medium temperature range–10 to +110 °C (+14 to +230 °F)
Ambient temperature range–10 to +60 °C (+14 to +140 °F)
Sensor housing materialDN 15 to 300 (½ to 12″): AlSi10Mg, coated
DN 350 to 600 (14 to 24″): Carbon steel with protective varnish
Transmitter housing materialAlSi10Mg, coated
Degree of protectionIP67, type 4X enclosure
Display/Operation4‐line backlit display available (no local operation)
Configuration via web browser and operating tools possible
Outputs4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
InputsNone
Digital communicationHART, PROFIBUS DP, Modbus RS485, EtherNet/IP, PROFINET
Power supplyDC 20 to 30 V
Hazardous area approvalsATEX, IECEx, cCSAus, INMETRO
Other approvals and certificates3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6 a (TÜV attestation)
PED

Leave a Reply