Endress+Hauser LPGmass Coriolis flowmeter

Endress+Hauser LPGmass Coriolis flowmeter

You are currently viewing Endress+Hauser LPGmass Coriolis flowmeter
persian
English

02 تیر 1401 17:50

جستجو

Endress+Hauser LPGmass Coriolis flowmeter

The refueling and distribution application flowmeter with easy system integration

The LPGmass is specially designed for flow measurement of LPG for dispensing and truck unloading. It combines an integrated temperature measurement with intelligent conversion functions, providing volume correction directly on site. LPGmass will be the preferred choice for system integrators, skid builders and equipment manufacturers.

Benefits

  • Excellent operational safety – reliable under extreme ambient conditions
  • Fewer process measuring points – multivariable measurement (flow, density, temperature)
  • Space-saving installation – no in/outlet run needs
  • Easy operation – reduced to application needs
  • Fast commissioning – pre-configured devices
  • Automatic recovery of data for servicing

Field of application

  • Measuring principle operates independently of physical fluid properties such as viscosity or density
  • Accurate measurement of liquefied petroleum gas in refueling and distribution applications.

Device properties

  • Flow rates up to 45 000 kg/h (1654 lb/min)
  • Volume flow calculation according to API table 53
  • Worldwide metrological approvals
  • Robust, ultra-compact transmitter housing
  • Pulse output and Modbus RS485
  • Transmitter for custody transfer
Measuring PrincipleCoriolis
Product headlineThe refueling and distribution application flowmeter with easy sytem integration. Accurate measurement of liquefied petroleum gas in refueling and distribution applications.
Sensor featuresExcellent operational safety – reliable under extreme ambient conditions. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Flow rates up to 45 000 kg/h (1654 lb/min). Volume flow calculation according to API table 53.
Transmitter featuresEasy operation – reduced to application needs. Fast commissioning – pre‐configured devices. Automatic recovery of data for servicing. Robust, ultra‐compact transmitter housing. Pulse output and Modbus RS485.
Nominal diameter rangeDN 8 to 40 (³⁄₈ to 1½”)
Wetted materialsMeasuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Measured variablesMass flow, density, temperature, volume flow, corrected volume flow
Max. measured errorMass flow (liquid): ±0.2 %
Volume flow (liquid): ±0.3 %
Measuring range0 to 45 000 kg/h (0 to 1650 lb/min)
Max. process pressurePN 40, Class 300, 63K
Medium temperature range–40 to +125 °C (–40 to +257 °F)
Ambient temperature range–40 to +60 °C (–40 to +140 °F)
Sensor housing material1.4301 (304), corrosion resistant
Transmitter housing materialPowder‐coated die‐cast aluminium
Degree of protectionIP67, type 4X enclosure
Display/OperationNo local operation
Configuration via operating tools possible
OutputsPulse/frequency/switch output (passive), phase‐shifted pulse
InputsNone
Digital communicationModbus RS485
Power supplyDC 10 to 30 V
AC 20 to 28 V
Hazardous area approvalsATEX, IECEx, NEC/CEC, FM, CSA, NEPSI, UL
Other approvals and certificates3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), custody transfer
PED, CRN

Leave a Reply

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.