The ControlLogix architecture provides a wide range of input and output modules to span many applications, from high-speed digital to process control. The ControlLogix architecture uses Producer-Consumer technology, which allows input information and output status to be shared among multiple ControlLogix controllers.

Each ControlLogix I/O module mounts in a ControlLogix chassis and requires either a removable terminal block (RTB) or a 1492 interface module (IFM) to connect all field-side wiring. RTBs and IFMs are not included with the I/O modules. They must be ordered separately.

Environmentals and Certifications

ControlLogix I/O Modules Environmental Specifications

 ControlLogix I/O Modules
Operating Temperature0…60 °C (32…140 °F)
Storage temperature-40…85 °C (-40…185 °F)
Relative Humidity5…95% noncondensing
Vibration2 g at 10…500 Hz
Operating Shock30 g
Nonoperating Shock50 g



ControlLogix I/O Modules Certifications



Certifications: (When product is marked.) c-UL-us, CE, CSA, C-Tick, FM, ATEX, TÜV.

See the Product Certifications link at ab.rockwellautomation.com/ for Declarations of Conformity, Certificates, and other certification details. For TÜV and SIL certification details, see the Safety Certificates and SIL link.

Digital I/O Modules



The 1756 digital I/O modules support these features.

  • Variety of voltage interface capabilities
  • Isolated and nonisolated module types
  • Point-level output fault states
  • Direct-connect or rack-optimized communication
  • Field-side diagnostics on select modules



In addition, you can select these types of digital I/O modules.

Digital I/O TypeDescription
DiagnosticThese modules provide diagnostic features to the point level. These modules have a D at the end of the catalog number.
Electronic fusingThese modules have internal electronic fusing to prevent too much current from flowing through the module. These modules have an E at the end of the catalog number.
Individually isolatedThese modules have individually isolated inputs or outputs.
These modules have an I at the end of the catalog number.



Digital AC Input Modules

Cat. No.Inputs/OutputsVoltage CategoryOperating Voltage RangeRemovable Terminal Block
1756-IA8D8 diagnostic inputs (4 points/group)120V AC79…132V AC1756-TBNH
1756-TBSH
1756-IA1616 inputs (8 points/group)120V AC74…132V AC1756-TBNH
1756-TBSH
1756-IA16KConformal coated 16 inputs (8 points/group)120V AC74…132V AC1756-TBNH
1756-TBSH
1756-IA16I16 individually isolated inputs120V AC74…132V AC1756-TBCH
1756-TBS6H
1756-IA16IKConformal coated 16 individually isolated inputs120V AC74…132V AC1756-TBCH
1756-TBS6H
1756-IA3232 diagnostic inputs (4 points/group)120V AC74…132V AC1756-TBCH
1756-TBS6H
1756-IM16I16 individually isolated inputs240V AC159…265V AC1756-TBCH
1756-TBS6H
1756-IM16IKConformal coated 16 individually isolated inputs240V AC159…265V AC1756-TBCH
1756-TBS6H
1756-IN1616 inputs (8 points/group)24V AC10…30V AC1756-TBNH
1756-TBSH
  



Digital AC Output Modules

Cat. No.Inputs/OutputsVoltage CategoryOperating Voltage RangeRemovable Terminal Block
1756-OA88 outputs (4 points/group)120/240V AC79…265V AC1756-TBNH
1756-TBSH
1756-OA8D8 diagnostic, electronically fused outputs (4 points/group)120V AC74…132V AC1756-TBNH
1756-TBSH
1756-OA8E8 electronically fused outputs (4 points/group)120V AC74…132V AC1756-TBNH
1756-TBSH
1756-OA1616 mechanically fused/group outputs (8 points/group)120/240V AC74…265V AC1756-TBNH
1756-TBSH
1756-OA16KConformal coated 16 mechanically fused/group outputs (8 points/group)120/240V AC74…265V AC1756-TBNH
1756-TBSH
1756-OA16I16 individually isolated outputs120/240V AC74…265V AC1756-TBCH
1756-TBS6H
1756-OA16IKConformal coated 16 individually isolated outputs120/240V AC74…265V AC1756-TBCH
1756-TBS6H
1756-ON88 outputs (4 points/group)24V AC10…30V AC, current >50 mA
16…30V AC, current <50 mA
1756-TBNH
1756-TBSH
  



Digital DC Input Modules

Cat. No.Inputs/OutputsVoltage CategoryOperating Voltage RangeRemovable Terminal Block
1756-IB1616 inputs (8 points/group)12/24V DC sink10…31.2V DC1756-TBNH
1756-TBSH
1756-IB16KConformal coated 16 inputs (8 points/group)12/24V DC sink10…31.2V DC1756-TBNH
1756-TBSH
1756-IB16D16 diagnostic inputs (4 points/group)12/24V DC sink10…30V DC1756-TBCH
1756-TBS6H
1756-IB16DKConformal coated 16 diagnostic inputs (4 points/group)12/24V DC sink10…30V DC1756-TBCH
1756-TBS6H
1756-IB16I16 individually isolated inputs12/24V DC sink/source10…30V DC1756-TBCH
1756-TBS6H
1756-IB16IF16 individually isolated fast inputs24V DC sink/source10…30V DC1756-TBCH
1756-TBS6H
1756-IB16IFKConformal coated 16 individually isolated fast inputs24V DC sink/source10…30V DC1756-TBCH
1756-TBS6H
1756-IB16ISOE16 individually isolated, sequence of events inputs24/48V DC sink/source10…55V DC1756-TBCH
1756-TBS6H
1756-IB3232 inputs (16 points/group)12/24V DC sink10…31.2V DC1756-TBCH
1756-TBS6H
1756-IB32KConformal coated 32 inputs (16 points/group)12/24V DC sink10…31.2V DC1756-TBCH
1756-TBS6H
1756-IC1616 inputs (8 points/group)48V DC sink30…55V DC at 60 °C
30…60V DC at 55 °C
1756-TBNH
1756-TBSH
1756-IG1616 inputs (8 points/group)5V DC TTL source (Low=True)4.5…5.5V DC1756-TBNH
1756-TBSH
1756-IH16I16 individually isolated inputs125V DC sink/source90…146V DC1756-TBCH
1756-TBS6H
1756-IH16ISOE16 individually isolated, sequence of events inputs125V DC sink/source90…140V DC1756-TBCH
1756-TBS6H
1756-IV1616 inputs (8 points/group)12/24V DC source10…30V DC1756-TBNH
1756-TBSH
1756-IV3232 inputs (16 points/group)12/24V DC source10…30V DC1756-TBCH
1756-TBS6H
  



Digital DC Output Modules

Cat. No.Inputs/OutputsVoltage CategoryOperating Voltage RangeRemovable Terminal Block
1756-OB88 outputs12/24V DC source10…30V DC1756-TBNH
1756-TBSH
1756-OB8EI8 electronically fused, individually isolated outputs12/24V DC source10…30V DC1756-TBCH
1756-TBS6H
1756-OB16D16 diagnostic outputs (8 points/group)24V DC source19.2…30V DC1756-TBCH
1756-TBS6H
1756-OB16DKConformal coated 16 diagnostic outputs (8 points/group)24V DC source19.2…30V DC1756-TBCH
1756-TBS6H
1756-OB16E16 electronically fused outputs (8 points/group)12/24V DC source10…31.2V DC1756-TBNH
1756-TBSH
1756-OB16EKConformal coated 16 electronically fused outputs (8 points/group)12/24V DC source10…31.2V DC1756-TBNH
1756-TBSH
1756-OB16I16 individually isolated outputs12/24V DC sink/source10…30V DC1756-TBCH
1756-TBS6H
1756-OB16IS16 individually isolated outputs
8 scheduled outputs
12/24V DC sink/source10…30V DC1756-TBCH
1756-TBS6H
1756-OB16IEF16 individually isolated, electronically-fused fast outputs12/24V DC sink/source10…30V DC1756-TBCH
1756-TBS6H
1756-OB16IEFKConformal coated 16 individually isolated, electronically-fused fast outputs12/24V DC sink/source10…30V DC1756-TBCH
1756-TBS6H
1756-OB3232 outputs (16 points/group)12/24V DC source10…31.2V DC1756-TBCH
1756-TBS6H
1756-OB32KConformal coated 32 outputs (16 points/group)12/24V DC source10…31.2V DC1756-TBCH
1756-TBS6H
1756-OC88 outputs (4 points/group)48V DC source30…60V DC1756-TBNH
1756-TBSH
1756-OG1616 outputs (8 points/group)5V DC TTL Source (Low=True)4.5…5.5V DC1756-TBNH
1756-TBSH
1756-OH8I8 individually isolated outputs120V DC90…146V DC1756-TBCH
1756-TBS6H
1756-OV16E16 electronically fused outputs (8 points/group)12/24V DC sink10…30V DC1756-TBNH
1756-TBSH
1756-OV32E32 electronically fused outputs (16 points/group)12/24V DC sink10…30V DC1756-TBCH
1756-TBS6H
  



Contact Output Modules

Cat. No.Inputs/OutputsOperating Voltage RangeRemovable Terminal Block
1756-OW16I16 N.O. individually isolated outputs5…150V DC
10…265V AC
1756-TBCH
1756-TBS6H
1756-OW16IKConformal coated 16 N.O. individually isolated outputs5…150V DC
10…265V AC
1756-TBCH
1756-TBS6H
1756-OX8I8 N.O.
8 N.C. individually isolated outputs
(2 points/group)
5…150V DC
10…265V AC
1756-TBCH
1756-TBS6H
  